Characteristics
Requirements to GOST
Ð 51204-98
Real characteristics
(according to results of testing at Russian Inst. for Electr.Engin. -VEI)
1. Nominal voltage, kV
25 25
2. Leakage distance, m
0,8
0,8
3. Normalized breaking pulling load, kN, not less than
120
143

4. Short-time (one-minute) power-frequency voltage, kV:

— in dry state

145
292
— under the rain, aflat/upright
125/70
193/166

5. Testing voltage, kV:

— of lightning impulse

+240, -240
+390, -390
— of power frequency, in wet and dirty state
40
55
6. Insulator weight, kg
-
1,7
7. Atmospheric pollution level
III-VII
III-VII

Product quality management system complies with requirements GOST R ISO 9001-2001.

Certificate No. ÑÑÔÆÒ RU.0004.È.00029

Diplomas

 Diplom  Diplom

Products and proposals
Railways
Highways
Bridge engineering
Infrastructure
Power engineering and communication
Transport
Construction profiles
Renovation and repairing
Subway
Catalogue of products
About Company
Mission
Structure
History
Partners
Awards
Special economic zone
Science & Technology Testing Center
Nanotechnologies
Adhesive prepregs
Polymer resins
Mathematical simulation
Vacuum infusion
Pultrusion
Testing and approval
Mass Production
Mass production technologies
Mass products
Competitive advantage of composite materials
Press Center
News
Contacts
 
November 29th, 2013

November 26th, 2013

November 1th, 2013

RailwaysHighwaysBridge engineeringInfrastructurePower engineering and communicationTransportSubway
+7 (495) 287-12-92; 287-12-93; 287-12-94
© Apatech — Applied Advanced Technology Company Ltd., 2005—2007. All rights reserved.
Russia, 107078, Moscow,
Novaia Basmannaia 14 str. 2